Wednesday 5 June 2024

Technical Specification Sheet: Honey Conversion Table

 


Technical Specification Sheet: Honey Conversion Table

1. Overview

This technical specification sheet provides a comprehensive conversion table illustrating the relationship between the % moisture, specific gravity, °Brix, and refractive index of honey at 20°C. The moisture content or soluble solids in honey are typically determined by measuring the refractive index using a refractometer.

2. Importance

The refractive index of honey differs from that of a sucrose solution at the same concentration, necessitating a unique moisture chart for accurate determination. This table assists in correlating these parameters to ensure precise measurement and quality control in honey processing and analysis.

3. Conversion Table

% Moisture

Specific gravity

(20°C)

°Brix at 20°C

(refractometer 0 - 90 range)

Refractive index at 20°C

13

1.4525

85.66

1.5041

13.2

1.451

85.45

1.5035

13.4

1.4495

85.24

1.503

13.6

1.4481

85.03

1.5025

13.8

1.4466

84.82

1.502

14

1.4453

84.61

1.5015

14.2

1.4438

84.39

1.501

14.4

1.4428

84.18

1.5005

14.6

1.4409

83.97

1.5

14.8

1.4395

83.76

1.4995

15

1.4381

83.55

1.499

15.2

1.4367

83.34

1.4985

15.4

1.4352

83.13

1.498

15.6

1.4338

82.92

1.4975

15.8

1.4324

82.71

1.497

16

1.431

82.5

1.4965

16.2

1.4295

82.29

1.496

16.4

1.4282

82.08

1.4955

16.6

1.4267

81.87

1.495

16.8

1.4254

81.66

1.4945

17

1.4239

81.45

1.494

17.2

1.4225

81.25

1.4935

17.4

1.4212

81.04

1.493

17.6

1.4197

80.83

1.4925

17.8

1.4184

80.63

1.492

18

1.4171

80.42

1.4915

18.2

1.4156

80.21

1.491

18.4

1.4143

80.01

1.4905

18.6

1.4129

79.8

1.49

18.8

1.4115

79.59

1.4895

19

1.4101

79.39

1.489

19.2

1.4087

79.18

1.4885

19.4

1.4074

78.97

1.488

19.6

1.406

78.77

1.4876

19.8

1.4046

78.56

1.4871

20

1.4033

78.35

1.4866

20.2

1.402

78.15

1.4862

20.4

1.4006

77.94

1.4858

20.6

1.3992

77.74

1.4853

20.8

1.3979

77.53

1.4849

Ref: Data from the table complied by H.D. Chetaway. National Research Laboratories - Ottawa. Temperature corrections are as follows: Specific Gravity = .0006 per °C or .00033 per °F; °Brix value = .09 per ° C or .05 per ° F; Refractive Index = .00023 per °C or .00013 per °F. If the temperature is above 20°C, add the correction; if it is below 20°C subtract the correction

4. Detailed Descriptions

% Moisture:

  • Indicates the percentage of water content in honey.
  • A critical parameter for assessing the quality and preservation of honey.

Specific Gravity (20°C):

  • The ratio of the density of honey to the density of water at 20°C.
  • Used to determine the concentration of soluble solids in honey.

°Brix at 20°C:

  • Represents the sugar content of an aqueous solution.
  • Measured using a refractometer, °Brix indicates the percentage of dissolved solids in honey.

Refractive Index at 20°C:

  • A measure of how much light is bent, or refracted, when entering the honey solution.
  • This parameter helps in identifying the concentration of soluble solids and moisture content.

5. Measurement Procedure

  1. Sample Preparation:
    • Ensure the honey sample is at a uniform temperature of 20°C.
    • If necessary, warm the honey slightly to reduce viscosity and achieve a homogenous sample.
  2. Using a Refractometer:
    • Calibrate the refractometer according to the manufacturer’s instructions.
    • Place a drop of honey on the refractometer prism.
    • Close the prism cover and allow the sample to spread evenly across the surface.
    • Read the refractive index directly from the refractometer scale.
  3. Interpreting Results:
    • Use the refractive index obtained from the refractometer to find the corresponding °Brix value from the table.
    • Match the °Brix value to the specific gravity and % moisture content for precise analysis.

6. Application

This conversion table is essential for:

  • Quality control in honey production.
  • Ensuring compliance with food safety standards.
  • Research and development in food science.
  • Accurate labeling and marketing of honey products.

7. References

  • The values in this table are derived from standard measurements and may vary slightly based on specific conditions and honey varieties.
  • For further details, refer to industry guidelines and refractometer manufacturer manuals.

8. Notes

  • Ensure all measurements are conducted at the specified temperature (20°C) for accuracy.
  • Regular calibration and maintenance of refractometers are crucial for reliable results.

By following this technical specification, users can accurately determine the quality parameters of honey, ensuring consistency and compliance with industry standards.